Adding target disk LUNs for encryption
2
4. Select the target port from the Target Port table.
5. Click Next.
The Select Initiator Port dialog box displays.
FIGURE 54 Select Initiator Port dialog box
6. Select the initiator port from the Initiator Port table.
7. Cl ic k Next.
LUN discovery is launched and a progress bar displays. There are four possible outcomes:
- A message displays indicating no LUNs were discovered. Click OK to dismiss the message
and exit the wizard.
- A message displays indicating LUNs have been discovered, but are already configured.
Click OK to dismiss the message and exit the wizard.
- A message displays indicating that the target is not in the right state for discovering LUNs.
Click OK to dismiss the message and exit the wizard.
- The Select LUN dialog box displays, showing discovered LUNs that are available. Select the
LUN from LUN list.
8. Click Finish.
The new LUN path is added to the Encryption Disk LUN view.
In environments where there are multiple paths to the same LUNs, it is critical that the same LUN
policies are configured on all instances of the LUN. Be sure to return to the Encryption Disk LUN
View dialog box to determine if there are configuration mismatches. Check under Encryption Mode
for any entries showing Mismatch. To correct the mismatch, click the incorrect mode to display the
options (as shown in the figure), then select the correct mode.