11.5 HP StoreVirtual Storage Release Notes

If an online upgrade failed, the CMC issued a reboot for the storage system to stop the upgrade
server process.
If the frame size entered is more than 1500, a hyperlink to a warning message is now displayed.
LeftHand OS
Unassigning multiple FC volumes (10 or more) simultaneously could cause the storage system to
become unresponsive.
For the 4330, fixed an issue with setting the controller cache ratio properly after the capacitor is
fully charged and the controller cache is enabled.
User login hung after configuring a management group for Active Directory access.
During load balancing, an iSCSI initiator could lose connectivity to a volume or snapshot for up
to 30 minutes. This was caused by the storage system with the VIP address rebooted or lost network
connectivity.
During an upgrade to Version 10.5, the iSCSI connections would close on the initiator, resulting
in loss of access to volumes and required a manual restart of the storage systems.
When creating a managed snapshot using a third party backup application, the snapshot did
not inherit the same server assignments as the parent volume, which caused backups to fail.
If auto rebalance of iSCSI sessions has been disabled and the storage system with the iSCSI VIP
fails, an unexpected iSCSI session auto rebalance could occur.
Reduced the size of the support bundle by removing the AHS logs that were captured on every
storage server in the group. If AHS logs are required, HP Support can generate them using the
storage server iLO interface.
HP P4300 G2, HP P4500 G2, HP P4800 G2, and HP P4900 G2 storage systems would reboot
twice instead of once when a NC552SFP 10 GbE NIC was installed.
Fixed an issue with Failover Managers that boot from SAN volumes and experience poor I/O
performance, resulting in manager timeouts or hung I/O. The fix removes the FOM from quorum
decisions on the cluster.
StoreVirtual VSA Installer
Fixed an issue that caused the HP StoreVirtual VSA for VMware vSphere to fail if the configuration
contained NFS datastores.
Prerequisites
The patches listed in Table 1 (page 9) are prerequisites for upgrading to 11.x and they are installed
automatically through the Online Upgrade feature. Firmware patches are only installed if necessary
for your hardware.
Table 1 Prerequisite patches for upgrading
DescriptionPatch
Delivers the latest HP Smart Array P410 RAID controller firmware (5.70).10136–00
Delivers the latest HP Smart Array P410i RAID controller firmware (5.70).10137–00
Only installable on 10.5 systems and required for any upgrades from 10.5.10147–00
Update for LeftHand OS versions 10.0 or later. Updates the iLO firmware version to 1.22 and fixes an
issue with the sensors not working when the BIOS level is incompatible with the system's iLO version and
the iLO driver in the LeftHand OS software.
10156–00
This patch updates the Emulex 10 GbE NIC firmware version to 4.9.311.10174–00
Prerequisites 9