HP StorageWorks LUN Configuration and Security Manager XP user guide for the XP12000/XP10000/SVS200 LUN Manager and Volume Manager (T1714-96015, October 2007)

Secret: Secret (that is, a password used in CHAP authentication) between 12 to 32
characters. You can use alphanumeric characters.
Re-enter Secret: Specify the secret, again, for conrmation.
5. Click OK.
6. Click Apply.Aconrmation message appears.
7. Click OK. Settings are applied to the array.
Clearing a Fibre Channel switch's user information
1. Start LUN Man
ager, and display the Authentication pane (Figure 30).
2. In the Port t
ree, double-click the Subsystem folder. If the array contains Fibre Channel adapters, the
Fibre folder appears below the Subsystem folder.
3. In the Port tree, double-click the Fibre folder. Information about the Fibre Channel switch appears in
the FC Switc
h Information list.
4. Right-click any point in the FC Switch Information list, and select ClearUserinformation.TheClear
Authentication Information pane appears.
Figure
70 Clear Authentication Information pane
5. Click OK.
6. Click Apply.Aconrmation message appears.
7. Click OK. Settings are applied to the array.
Specifying a Fibre Channel switch's authentication mode
1. Start LUN Manager, and display the Authentication pane (Figure 30).
2. In the Port tree, double-click the Subsystem folder. If the array contains Fibre Channel adapters, the
Fibre folder appears below the Subsystem folder.
3. In the Port tree, double-click the Fibre folder. Information about the Fibre Channel switch appears in
the FC Switch Information list.
4. Right-click any point in the FC Switch Information list, and select Authentication
unidirectional->bi-directional.
5. Click Apply.Aconrmation message appears.
HP StorageWorks LUN Conguration and Security Manager XP user guide for the
XP12000/XP10000/SVS200
123