HP StorageWorks LUN Configuration and Security Manager XP user guide for the XP12000/XP10000/SVS200 LUN Manager and Volume Manager (T1714-96015, October 2007)

NOTE:
Round up the value enclosed by two up arrows () to the nearest whole number.
•Theuser-specied CV capacity is expressed in blocks.
The management area capacity is expressed in kilobytes. The management area capacity
depends on volume emulation types (see Table 27).
The boundary value is expressed in kilobytes. The boundary value depends on volume emulation
types and RAID levels (see Table 28).
Table 26 Management area capacity of mainframe volumes
Emulation type
Management area capacity
3380-3, 3380-3A, 3380-3B, 3380-3C,
3380-K,3380-KA,3380-KB,3380-KC,
NF80-K,NF80-KA,NF80-KB,NF80-KC
7
3390-3, 3390-3R, 3390-3A, 3390-3B, 3390-3C
6
3390-9, 3390-9A, 3390-9B, 3390-9C
25
3390-L, 3390-LA, 3390-LB, 3390-LC
23
3390-M,3390-MA,3390-MB,3390-MC
53
3380-F, NF80-F
22
NOTE:
A mainframe volume's management area capacity is expressed in cylinders.
Table 27 Management area capacity of open-system volumes
Emulation type
Management area capacity
OPEN-V
0
OPEN-3
5,760
OPEN-8 19,440
OPEN-9 19,440
OPEN-E
13 ,6 8 0
NOTE:
An open-system volume's management area capacity is expressed in kilobytes.
HP StorageWorks LUN Conguration and Security Manager XP user guide for the
XP12000/XP10000/SVS200
151