HP StorageWorks LUN Configuration and Security Manager XP user guide for the XP12000/XP10000/SVS200 LUN Manager and Volume Manager (T1714-96015, October 2007)

Figure 7 FC-AL and Point-to-point topologies
When conguring the system, use the LUN Manager pane to specify whether the hosts and array are
connected by a fabric switch.
If you use a fabric switch, you must specify FC-AL or point-to-point in the LUN Manager pane (by default,
FC-AL is specied). If you use a fabric switch, see the fabric switch's documentation to learn whether
you shou
ld use FC-AL or point-to-point. Some fabric switches require that you specify point-to-point to
get the system running.
If you are not using a fabric switch, you must specify FC-AL. For more information, see Specifying Fibre
Channel topologies.
Fibre Channel port addresses
When conguring the system, you must set addresses for Fibre Channel ports. When addressing Fibre
Channel ports, you can use the AL-PA (arbitrated-loop physical address) or loop ID as the address
(see Table 2).
For more information, see Addressing Fibre Channel ports.
HP StorageWorks LUN Conguration and Security Manager XP user guide for the
XP12000/XP10000/SVS200
27