Table 17 Host mode options
No.
Host mode option When to select this option
2
VERITAS Database
Edition/Advanced
Cluster
When
VERITAS Database Edition/Advanced Cluster for Real
Appl
icationClustersorVERITASClusterServer4.0(I/Ofencing
function) is used
6TPRLO
When all the following conditions are satised:
Hostmode0CWindowsor2CWindowsExtensionisused
Emulex host bus adapters are used
Mini-port drivers are used
TPRLO=2 is specied for the host bus adapter's mini-port driver
parameter
7
Automatic recognition
function of LUN
When all the following conditions are satised:
Host mode 00 Standard or 09 Solaris is used
SUN StorEdge SAN Foundation Software Version 4.2 or later is used
You want to automate recognition of increase and decrease of
devices when a genuine SUN HBA is connected
12
Undisplay function of
ghost LUN
When all the following conditions are satised:
Host mode 03 HP is used
You want to suppress creation of device les for devices to which
paths are not dened
13
SIMreportatlinkfailure Whenyouwanttobeinformedbyserviceinformationmessage(SIM)
that the number of link failures detected between ports exceeds the
threshold.
14
HP TruCluster with
Continuous Access XP
function
When all the following conditions are satised:
Host mode 07 Tru64 is used
You want to use TruCluster to set a cluster to the Continuous Access
XP P-VOL and S-VOL, respectively
19
VMware
WhenregisteringVMwareserverhostsinthehostgroup,makesure
to select this option.
24 2TB or Larger LUN
Support
When one of the following operating systems is installed on the hosts,
and the hosts are to access LUs larger than 2 TB:
AIX 5.2 TL08 or later
AIX 5.3 TL04 or later
Windows Server 2003 SP1 or later
Red Hat Enterprise Linux AS 4 Update 1 or later
CAUTION:
Other operating systems do not support LUs larger than 2 TB. If
other operating systems are used by hosts, make sure that LUs
are not larger than 2 TB.
CAUTION:
For information about the maximum LU capacity supported by
your operating system, contact the manufacturer of your operating
system.
Creating iSCSI targets (when conguring iSCSI environments)
You can connect multiple server hosts on different platforms to one port on the array. When conguring
the system, you must group server hosts connected to the array by iSCSI targets. For example, if HP-UX
andWindowshostsareconnectedtoaport,youmustcreateoneiSCSItargetforHP-UXhostsand
another iSCSI target for Windows hosts. Next, you must register HP-UX hosts to the corresponding iSCSI
target and register Windows hosts to the other iSCSI target.
84 LUN Manager operations