HP StorageWorks LUN Configuration and Security Manager XP user guide for the XP12000/XP10000/SVS200 LUN Manager and Volume Manager (T1714-96015, October 2007)
Figure 42 Add New iSCSI name pane (registering a host that has never been
connected to the array)
b. In the iSCSI name list, select the host bus adapter. If the list does not include the host bus
adapter, enter the iSCSI name in the iSCSI name box.
c. If necessary, enter a nickname for the host bus adapter.
d. Click OK.Thespecified iSCSI name and nickname appear below the selected iSCSI target.
4. Click Apply.Aconfirmation message appears.
5. Click OK. Settings are applied to the array, and the specified host is registered in the iSCSI target.
Associating host groups or iSCSI targets to logical volumes
Use LUN Manager to define LU paths by associating host groups or iSCSI targets to logical volumes. For
example, if you associate a host group or iSCSI target consisting of three hosts with logical volumes, LU
paths are defined between the three hosts and the logical volumes.
1. Start LU
N Manager. The LUN Manager pane (Figure 14 or Figure 15) appears.
2. In the tree, select a host group or iSCSI target.
NOTE:
If you are configuring a NAS environment, you must select the User host group.
3. In the CU list above the LDEV table, select a CU number. The LDEV table shows LDEVs in the
specified CU image.
4. In the LDEV table, select a logical volume. In the LU Path table, select LUNs indicated by the
icon
(thisiconindicatesaLUNtowhichnoLUpathisdefined). Click Add LU Path.
A message appears displaying information about LU paths to be defined.
NOTE:
• If you are using Windows, you can drag a logical volume from the LDEV table to
aLUN(
)intheLU Path tree. To drag more than one logical volume, see the
HP
StorageWorks Command View XP user guide for XP Disk Arrays
or the
HP StorageWorks
XP Remote Web Console user guide for XP12000/XP10000/SVS200
for instructions.
•WhenyouusetheLU Path tree, you can use the CU list to switch between CU images.
90
LUN Manager operations