HP StorageWorks LUN Configuration and Security Manager XP user guide for the XP12000/XP10000/SVS200 LUN Manager and Volume Manager (T1714-96015, October 2007)

3. In the tree, select a host group or iSCSI target. The LU Path table displays information about LU paths
associated with the selected host group or iSCSI target.
4. In the LU Path table, select one or more LUNs to which volumes are assigned. (If a volume is assigned
to a LUN, columns on the right of the LUN column are not empty.)
5. Right-click the selection, and select Release LU Path.Aconrmation message appears.
Figure 45 Information about LU paths to be deleted (Fibre Channel environments)
Figure 46 Information about LU paths to be deleted (iSCSI environments)
6. Click OK. The selected LU path is removed from the table.
7. Click Apply.Aconrmation message appears.
8. Click OK. Settings are applied to the array, and the specied LU paths are deleted.
NOTE:
If you delete numerous paths at one time, the deletion process might take time and the pane
migh
t seem to hang temporarily.
92
LUN Manager operations