HP StorageWorks LUN Configuration and Security Manager XP user guide for the XP12000/XP10000/SVS200 (T1714-96008, June 2006)

LUN Configuration and Security Manager XP user guide for the XP12000/XP10000/SVS200 111
5. Click OK.
6. Click Apply. A confirmation message appears.
7. Click OK. Settings are applied to the array.
Clearing a Fibre Channel switch’s user information
1. Start LUN Manager, and display the Authentication pane (Figure 30).
2. In the Port tree, double-click the Subsystem folder. If the array contains Fibre Channel adapters, the
Fibre folder appears below the Subsystem folder.
3. In the Port tree, double-click the Fibre folder. Information about the Fibre Channel switch appears in
the FC Switch Information list.
4. Right-click any point in the FC Switch Information list, and select Clear User information. The Clear
Authentication Information pane appears.
Figure 70 Clear Authentication Information pane
5. Click OK.
6. Click Apply. A confirmation message appears.
7. Click OK. Settings are applied to the array.
Specifying a Fibre Channel switch’s authentication mode
1. Start LUN Manager, and display the Authentication pane (Figure 30).
2. In the Port tree, double-click the Subsystem folder. If the array contains Fibre Channel adapters, the
Fibre folder appears below the Subsystem folder.
3. In the Port tree, double-click the Fibre folder. Information about the Fibre Channel switch appears in
the FC Switch Information list.
4. Right-click any point in the FC Switch Information list, and select Authentication
unidirectional->bi-directional.
5. Click Apply. A confirmation message appears.
6. Click OK. Settings are applied to the array.
To return the Fibre Channel setting, perform the same operation, except select Authentication
bi-directional->unidirectional in step 4.
Specifying whether a Fibre Channel switch can perform authentication
To enable Fibre Channel switches to authenticate hosts, you must enable the Fibre Channel switch’s user
authentication settings. By default, Fibre Channel switch authentication is disabled.
To enable a Fibre Channel switch to authenticate hosts:
1. Start LUN Manager, and display the Authentication pane (Figure 30).