d. Click OK. The specified iSCSI name and nickname appear below the selected iSCSI target.
3. Click Apply. A confirmation message appears.
4. Click OK. Settings are applied to the array, and the specified host is registered in the iSCSI target.
Associating host groups or iSCSI targets to logical volumes
Use LUN Manager to define LU paths by associating host groups or iSCSI targets to logical volumes. For
example, if you associate a host group or iSCSI target consisting of three hosts with logical volumes, LU
paths are defined between the three hosts and the logical volumes.
1. Start LUN Manager. The LUN Manager pane (Figure 14 or Figure 15) appears.
2. In the tree, select a host group or iSCSI target.
NOTE: If you are configuring a NAS environment, you must select the User host group.
3. In the CU list above the LDEV table, select a CU number. The LDEV table shows LDEVs in the specified
CU image.
4. In the LDEV table, select a logical volume. In the LU Path table, select LUNs indicated by the icon
(this icon indicates a LUN to which no LU path is defined). Click Add LU Path.
A message appears displaying information about LU paths to be defined.
NOTE:
If you are using Windows, you can drag a logical volume from the LDEV table to a LUN ( ) in
the LU Path tree. To drag more than one logical volume, see the HP StorageWorks Command
View XP user guide for XP Disk Arrays or the HP StorageWorks XP Remote Web Console user
guide for XP12000/XP10000/SVS200 for instructions.