HP StorageWorks XP Data Integrity Check user guide for XP12000/XP10000/SVS200 (T1618-96004, December 2008)

2 D ata Integrity Check operating
environments an d prerequisites
Data Integrity Check requires the following:
A Command View XP array (see Requirements for the array)
A Host server that supports an Oracle database a nd has RAID Manager installed (see
Requirements for the Host Server)
An Oracle-data validation service (see Restrictions and Conventions )
Requirements for the array
Data Integrity Check requires a properly congured array and a channel adapter with the correct
microc ode.
Channel adapter (CH I P)
Data Integrity Check supports the following CHIP types:
DKC-F510-32HS (16 ports/PCB)
DKC-F510-16HS (8 ports/PCB)
CAUTION:
If CHIPs are used that do not support Data Integrity Check are used with CHIPs that do support Data
Integrity Check, the validity of the data is not checked when the data processed with the unsupported
CHIPs. HP recommends you to update all the CHIP s so that they would support Data Integrity Check.
Data Integrity Check license key
You need to install the license key for Data Integrity Check on the array using Remote Web Console. To
install the license key, refer to the HP StorageWorks XP Remote Web Console user guide.
Requirements for the host server
You will need the following items installed on the host server:
Fibre Channel interface
A Fibre Channel connection is required between the host server and the array.
RAID Manager
RAID Manager version 01-16-03/05 or b etter is required.
Operating system
One of the following operating systems is required.
HP StorageWorks Data Integrity Check XP user guide for the XP120 00/XP10000/SVS200
13