HP Insight Management 7.2 Update 2 Installation and Upgrade Release Notes

Environment Logical Server Storage Pool interface and checking the storage pool entry (SPE)
configuration.
If the SAN fabrics for server initiator WWNs are incorrect, correcting the SAN fabrics for
host initiators and saving the SPE this may address the problem. If the SAN fabrics are present
and are correct, merely modifying and saving the SPE can be a sufficient workaround to
address the problem. If the SAN fabrics are not available for the entries, you will need to
remove the SPE, deactivate and remove the associated SPM storage service, and then re-create
the SPE. Note the server initiator WWNs from the SPE, and then delete the SPE. Create a
new “SAN Catalog Storage Entry” SPE, and replace the auto-generated server initiator WWNs
with the noted values. Request candidates from SPM and make and appropriate selection.
The new SPM storage service should be conformant.
When SPM is installed, the sample XML files for unmanaged arrays and unmanaged SAN
operation are named as example.xml. When an upgrade from SPM 2.0 to SPM 2.2 is
performed, any file named example.xml that is present in the SPM state folder is removed
by the installer. It is important that you do not use the example.xml filename for your
production XML files, or you can risk losing that data when SPM is upgraded. If you have
used the example.xml file for naming for your production usage, you must back up this file
to a different location before performing the upgrade, and then restore the files to their proper
location in the state folder following the upgrade.
Installing Insight Management
Before beginning a new installation of Insight Management, HP recommends that you gather the
information listed in the HP Insight Management 7.2 Preinstallation Worksheet. Gathering the data
before you begin ensures that you are prepared to supply all input required during the installation.
See the HP Insight Management 7.2 Installation and Configuration Guide for installation instructions
and how to configure managed systems after Insight Management is installed.
Installation and upgrade times
The HP Insight Management 7.2 Installation and Configuration Guide lists approximate installation
and upgrade times for individual Insight Management components on an x86 and an x64 Operating
Systems.
Disabling virus scanners before beginning an installation
HP recommends that you disable virus-scanning software and backup agents before beginning the
installation process. Some Insight Management components might not install, if virus-scanning
software and/or backup agents are running.
Installation notes
The following list contains general notes that apply to a new installation of Insight Management.
Read these notes before you begin an installation.
On a system that has Windows 2008 R2 as its operating system, if the FTP site is not running,
the Default FTP site state test in the Insight Management Advisor displays No problems
found message instead of returning an error.
Suggested action: IIS does not provide proper FTP site status. For more information about the
issue, see the following two links:
http://forums.iis.net/p/1183266/2002986.aspx#2002986
http://forums.iis.net/t/1186230.aspx
The Insight Management Advisor password expiration check may fail displaying the following
error message: A system error occurred calling NetUserGetInfo due to the fact that the
20 Installation and upgrade notes