HP Insight Management 7.3 Update 1 Support Matrix

Table 55 Requirements and capabilities for HP ProLiant BL servers (continued)
Intelligent
Power
Discovery
3
Data
Center
Power
Control
1, 2
Calibrated
Maximum
Power
Power
Metering
Data
Center
Thermal
Mapping
Dynamic
Power
Capping
Power
Regulator
Minimum system
BIOS version
Minimum
iLO or OA
firmware
version
Server
model
Opteron
6100)
NoneiLO 3
version 1.05
ProLiant
BL685c G7
and OA
version 3.10
(AMD
Opteron
6200)
NoneiLO 3
version 1.05
ProLiant
BL685c G7
and OA
version 3.10
(AMD
Opteron
6300)
1
Data Center Power Control works only on Primary Addresses of a system and cannot detect a system with a non-primary address.
If a system has IPv4 as a primary address and IPv6 as a non-primary address, Data Center Power Control only works with the IPv4
address.
2
For VMhost with only an IPv6 address. Data Center Power Control cannot perform a graceful shutdown of guests. It will only
shutdown the hosts.
3
The Intelligent Power discovery feature is not supported when iPDU is configured with IPv6 addresses only
4
For Enclosure Dynamic Power Capping, iLO 2 version 1.70 or later. Otherwise, iLO 2 version 2 1.30 or later.
For Enclosure Dynamic Power Capping, OA 2.30 or later. Otherwise, OA 1.30 or later.
5
When you are implementing power capping for HP BladeSystem, HP recommends that you use Enclosure Dynamic Power Capping
set through the Onboard Administrator or Insight Control power management user interface. To use Enclosure Dynamic Power
Capping, you must upgrade your iLO 2 firmware to version 1.70 or later and iLO 3 to version 1.0 or later. HP recommends that
you update your system ROM to version 10/1/2008 or later for iLO 2, and May 2010 or later for iLO 3 for G7 servers. For some
older BL460c servers, the iLO 2 firmware might not be able to automatically update the Dynamic Power Capping hardware circuit.
In these instances, the Onboard Administrator will compensate for the absence of the internal hardware circuit and continue to
guarantee circuit protection.
6
This server model does not support HP Dynamic Power Savings mode.
Table 56 Requirements and capabilities for HP ProLiant workstation blades
Intelligent
Power
Discovery
3
Data
Center
Power
Control
1, 2
Calibrated
Maximum
Power
Power
Metering
Data
Center
Thermal
Mapping
Dynamic
Power
Capping
Power
Regulator
Minimum system
BIOS version
Minimum
iLO or OA
firmware
version
Server
model
4
8/5/2008iLO 2
version 1.60
or later.
ProLiant
xw2x220c
OA version
2.30 or
later.
5
7/31/2007iLO 2
version 1.30
or later
ProLiant
xw460c
7/31/2007iLO 2
version 1.30
or later
ProLiant
WS460c
G6