SPM adapter for EMC® Symmetrix® VMAX®: Matrix support for automation of EMC storage operations via the HP Storage Provisioning Manager
Technical white paper | SPM Adapter for EMC Symmetrix VMAX
16
The LUN value is invalid because VSA is enabled
• Possible Cause:
– When a VSA enabled port is used while presenting a LUN, the given LUN number (in hexadecimal value) is not valid or
not in sequence:
• The decimal numbers assigned for LUN numbers are converted into corresponding hexadecimal values. EMC
expects these values to be in sequence while presenting multiple LUNs to the same host.
• If VSA is enabled on a port, the hexadecimal value of the assigned LUN number should have its last digit in the range
0-7 if using Matrix 7.2.x.
• Suggested Actions:
– Contact the EMC administrator to get the next available LUN number to be assigned in sequence for a given port.
– Ensure that the hexadecimal value of the LUN number being assigned is in the range 1 – 7 if using Matrix 7.2.x. See the
note in the earlier Limitations section for more details.