HP Capacity Advisor 7.2 User Guide

9 Capacity Advisor error and warning messages
Certain messages that you might see when working within the Capacity Advisor user interface or
that are about data collected for use in Capacity Advisor are explained in this section. Messages
appearing in the user interface that are self-explanatory or that are supplied by the Utilization Data
Collection Events listing in Systems Insight Manager are not included here. For more information
on this Events list, see “Solving utilization data collection problems” (page 40).
Command error messages
Within the messages sections, messages appear in alphabetical order. Messages that start with
system_name are placed at “s” in a list.
During data import using the capprofile command, sample_time is the timestamp in local
time if the import profile includes it (YYYYMMDDhhmm), or the time in UTIS, if not.
NOTE: A message such as the following may precede other messages:
system_name: System information is not available to the WBEM provider. Collection from this
system cannot proceed until this situation is corrected. detailed_message
where system_name is the name of an HP-SIM managed node from the names specified on the
command line, and detailed_message is one of the Capacity Advisor messages.
For additional information, refer to the “Command reference” (page 193) in this guide, as well as
the HP Systems Insight Manager Help.
Table 27 Error messages and their correction
To correctPossible causeMessage
Use mxstart to start HP SIM on the
central management server.
HP SIM is not running.Could not access the HP SIM instance on
this system; nested exception is:
java.net.ConnectException: Connection
refused.
Ensure that the node is licensed, and
that appropriate permissions for the
node are set. Run vseassist to
troubleshoot connection errors. You can
also check the configuration of the
system(s) in the Insight managed system
setup wizard.
Permissions for this node are not
in place.
Error: Missing Capacity Advisor
authorization for node: system_name
Check access and process activity. Run
vseassist to troubleshoot connection
errors.
See message text.system_name: Another HP SIM Central
Management Server may be accessing
this system. CIM_ERR_NOT_FOUND: The
requested object could not be found:
Instance not found for RpID: FSS_3 and
datetime: date_time, GUID: n.
Run vseassist to troubleshoot
connection errors.
See message text.system_name: Error attempting to access
the WBEM server;
CIM_ERR_NOT_FOUND: The requested
object could not be found: Instance not
found for RpID: rpid and datetime:
2006...,GUID: n.
For systems running HP-UX 11.11,
apply patch PHSS_34428; for systems
running HP-UX 11.23, apply patch
PHSS_34429.
The system specified by
system_name during data
collection is running Version
2.00.09 of HP-UX WBEM Services
without required patches.
system_name: Error creating object.
Command error messages 173