HP Capacity Advisor 7.2 User Guide

Table 28 Warning messages in Capacity Advisor (continued)
To correctProbable causeMessage
Install the HP VM WBEM provider
(vmProvider) on the virtual machine or
correct the configuration problem.
For help with using vseassist, see
the HP Matrix Operating Environment
Getting Started Guide.
An HP virtual machine may be
discovered by HP SIM and labeled
as a standalone server if the
system does not have a properly
configured WBEM provider for HP
VMs. Such a system cannot be
collected from until it is discovered
by HP SIM correctly.
The system "system_name" has no
workload defined. Make sure to select
ToolsVSE Management...in HP SIM
before running this command for the first
time. For HPVM Guests, please be sure
that the HPVM WBEM provider is properly
configured. If problems persist, run
vseassist to further diagnose errors.
Verify that the name is spelled correctly
or add the system to HP SIM.
The system name specified on the
command line is not known to HP
SIM.
The system system_name was not found
in the HP SIM database.
Set authorizations as needed. For
information on user authorizations in
Matrix OE, see HP Matrix Operating
Environment Getting Started Guide.
See message text.The user has none of the required toolbox
authorizations on node cms_name, where
cms_name is the name of the CMS where
the command was run.
Make sure that:
1. Your user name has been added to
HP Systems Insight Manager.
2. Your user name and password, if
specified, are spelled correctly.
3. HP Systems Insight Manager is
running.
4. You used '--' for any long options
and double quotes if your user name
contains a domain, for example,
commandname– user
mydomain\myusername” –pass
mypassword
There was a problem connecting to the
HP SIM server.
The most recent sample is kept.More than one sample imported
with capprofile has the same
time stamp.
Values at duplicate sample time
sample_time replace previous values
for this time.
Redefine the workloads so that their
utilization limits fall within the resource
allocation for the system.
The sum of workload utilizations
exceeds system utilization.
Warning: Overlapping workload
definitions detected on system_name.
HP Smart Solver error messages
In situations where the Smart Solver is unable to produce a solution, one or more error messages
are displayed. Solver error messages are shown in red text on the user interface screen and describe
the issues that prevent a solution from being found.
When available systems lack sufficient capacity
When workloads cannot be placed on any system because the available systems lack sufficient
capacity in one or more resources, the workloads are excluded from the computation and listed
in the Smart Solver Excluded Systems table. A summary line is included that reports the minimum
system capacity required to place the workload(s).
Figure 9 Example of Smart Solver Excluded Systems table, part of the Smart Solver Results screen
176 Capacity Advisor error and warning messages