In this example, only a single vdisk is required by the storage pool entry. The names are kept the same
across the storage pool entry, the FC zone, the host entry on the array, and the vdisk. This approach
supports a strong correlation of the resources in the different tools. It is also possible to define a storage
pool entry with multiple LUNs. In this case, the naming of the vdisk could follow a pattern of a common
pre-fix (for example, e10_vc_w2k_1, 2, 3, 4, and so on). HP recommends selecting a naming convention,
and then following that pattern across all the tools.
Correcting a checksum error
If power is removed from the server during the power on sequence, an invalid checksum error might occur
in the Fibre Channel HBA firmware. If this error occurs, the following message appears during server power
up: