HP Insight Software 6.1 Support Matrix

CLX/XP (v3.0.1 or newer) must be installed on storage management station running either Microsoft
Windows 2003 or Microsoft Windows 2008.
Insight Recovery supports any XP array that is supported by CLX/XP.
NOTE: For the latest supported list of XP storage arrays and Microsoft Microsoft Windows OSs supported
by CLX/XP, see the following website:
http://www.hp.com/go/clxxp
Insight Recovery supports the following EVA arrays:
EVA 4000/4100/4400 with Continuous Access Synchronous Replication
EVA 6000/6100/6400 with Continuous Access Synchronous Replication
EVA 8000/8100/8400 with Continuous Access Synchronous Replication
NOTE: For Insight Recovery, Command View EVA version 8.0.2, 9.0.1, 9.1or 9.2 is required.
Firmware requirements
Table 3-4 lists minimum firmware requirements for Insight Control and Insight Dynamics.
NOTE: During development of Insight software 6.1, firmware maintenance CD version 9.1 was used.
Table 3-4 Minimum firmware requirements for Insight Control and Insight Dynamics
Minimum firmware versionItem
3.11HP BladeSystem c3000 Enclosure Onboard Administrator (OA)
3.11HP BladeSystem c3000 Tower Enclosure OA
3.11HP BladeSystem c7000 Enclosure OA
The minimum supported Virtual Connect firmware version
is 2.1x, with the following exception:
Virtual Connect firmware version 3.01 is required for HP
Integrity BL860c i2, BL870c i2, and BL890c i2 server
blades and HP ProLiant BL465c G7 and BL685c G7 server
blades.
NOTE: To download Virtual Connect firmware, go to the
following website:
http://h18004.www1.hp.com/products/blades/
components/vc-interconnects.html
HP Virtual Connect for BladeSystem c-Class
1.82
1
HP Integrated Lights-Out 2 Advanced (iLO 2) for ProLiant BladeSystem
3.15HP Integrated Lights-Out 2 (iLO 2) Advanced for Integrity
1.05HP Integrated Lights-Out 3 (iLO 3) Advanced for ProLiant BladeSystem
1.05HP Integrated Lights-Out 3 (iLO 3) Advanced for Integrity
5.38Baseboard Management Controller (BMC) Firmware
ProLiant BL460c and ProLiant BL480c servers require
System ROM 2007.06.28 or later
ProLiant BL465c and ProLiant BL685c servers require
System ROM 2007.04.05 or later
The ProLiant BL680c G5 server requires System ROM
2007.08.09 or later
All Integrity server blades require System Firmware:
04.21
Insight Dynamics requirements for server blades
1 Insight Control power management has been tested with firmware version 2.00.
28 Managed system requirements