HP Matrix Operating Environment 7.0 Release Notes

QLogic HBA (BIOS version 2.07 or higher)
RHEL 5.3 and higher
SLES 11 and higher
SLES 10 SP3 and higher
Windows 2003/2008: QLogic driver 9.1.7.29 or higher
Emulex HBA (BIOS version 3.11a3 or higher)
RHEL 5.4 or higher
SLES 10 SP3 or higher
SLES 11 in-box driver not yet available. Requires out-of-box Emulex driver version: 8.2.8.32
Windows 2003/2008: Emulex driver 5.00.17.06-2 or higher
Multipath I/O and Emulex FC HBA or Emulex FlexFabric Converged Network Adapter is not
supported on Windows Server 2008 and Windows Server 2008 R2
Using multipath I/O during OS installation is not supported with an Emulex FC HBA or an Emulex
FlexFabric Converged Network Adapter (CNA) on any Matrix-supported server on Windows Server
2008 and Windows Server 2008 R2.
The following suggested actions enable you to install the OS single-path and then modify the
storage definitions to create multiple-path access to the boot volume. After a successful OS
installation, these instructions will define an additional physical path to the boot volume by:
Modifying the storage definition to add an additional server HBA definition (port)
Modifying the boot volume definition to add a second physical path to its definition
Suggested action 1
If you are creating a template using Matrix OE infrastructure orchestration designer:
1. Do not select Redundant SAN paths to disk when configuring storage.
With this box unchecked, infrastructure orchestration will select a storage pool entry with a
single path, or will create a single-path storage pool entry during storage auto-generation.
If you are using SPM with pre-existing volumes or with on-demand provisioning, SPM will fulfill
the storage request with a volume presented over a single path and will only zone one path.
2. (Optional) Modify the storage pool entry to add on additional path. SPM will make the
appropriate adjustments.
Suggested action 2
If you are defining a storage pool entry in Matrix OE logical server management:
1. Define the storage pool entry, adding multiple ports, and marking all non-boot disks as
redundant. Keep the boot volume as a single path.
2. Assign the storage pool entry to a logical server.
3. Activate the logical server.
4. Provision the OS, and install the multipath IO drivers as appropriate.
5. Deactivate the logical server.
6. Modify the storage pool entry to make the boot volume redundant.
7. Reactivate the logical server.
Multi-initiator NPIV support on Integrity blades
Multi-initiator NPIV features used by Matrix OE and Virtual Connect Enterprise Manager are
supported on Integrity blades using the QLogic FC controller with the HP-UX 11i v3 Update 8
(March 2011) and later release. Multi-initiator NPIV features are not supported on Integrity blades
with Emulex FC controllers.
18 Issues and suggested actions