HP Integrity Virtual Server Manager 6.1 Release Notes

Table 1 Fixes in the Integrity Virtual Server Manager 6.1 release (continued)
DescriptionDefect ID
If HPVM DIOs are not added initially, the Specify DIOs page displays an error message to
add HPVM DIOs even though this is not a configuration error.
QXCR1001208970
Integrity Virtual Server Manager does not support 64-bit character vswitch name.QXCR1001208962
The Network and Storage tab display No Data even though the utilization bar in the Virtual
Servers tab displays that data is available.
QXCR1001173609
The Specify Intended Operating System type list box in Step 1 of the Create Virtual Machine
Wizard has ? as one of the OS options.
QXCR1001091146
Integrity VM 4.3PK2 displays Add DIO page.QXCR1001189798
The Note column in Step 1 of the Create Virtual Machine Wizard is not localized.QXCR1001197903
When creating or adding an NPIV device using the Integrity Virtual Server Manager, the
"Manual" string for selecting the WWNs is always misplaced and not close to its
corresponding radio button.
QXCR1001184508
If SIM is configured to require Trusted Certificates, and if the certificate to the HPVM host is
not available or invalid, Integrity Virtual Server Manager gives internal error when accessed
from the HPVM host.
QXCR1001208974
During HP-UX installation, a warning is displayed that VSEmgmt and HP SIM must not be
installed on the same system, if the system is used as a VM host.
QXCR1001007221
When the VM is ON, the AMR check state does not display the correct information in the
Modify Memory page.
QXCR1001190194
The Virtual Switches tab displays wrong information in the VM mode.QXCR1001175140
The functions that are not supported in Integrity VM 4.3 LR are not disabled.QXCR1001173633
VMMGR installation fails on systems with Tomcat 2.2 with Apache 2.2. Prerequisite for
VMMGR installation to be changed to include versions of Tomcat and Apache other than
2.0.
QXCR1001084743
When the memory size of the guest is very large, the percentage data is missing in memory
utilization.
QXCR1001196877
In Integrity Virtual Server Manager on SMH 6.1, the Modify Network/Storage page is linked
to a wrong help file.
QXCR1001216369
In Integrity Virtual Server Manager on SMH 6.1, the Enable dynamic control value displayed
is incorrect in the General Preview table.
QXCR1001217210
In the VM General properties page, the information section displays incorrect data about the
memory unit utilization.
QXCR1001198713
In the Add storage page, when adding storage, you must filter the device which does not
support NPIV.
QXCR1001183559
When the storage type used is of type DVD (directory), you cannot create vPars.QXCR1001177865
Known problems, limitations, and workarounds
This section provides a list of known problems and limitations as known to HP at time of publication.
If workarounds are available, they are included.
Character limitation for virtual switch name
In Integrity Virtual Server Manager installed on Integrity VM v4.3 PK2 and PK3, virtual switch
name cannot exceed eight characters. This behavior exists on Integrity Virtual Server Manager
on SMH and SIM.
Severity: Medium
6