Building Disaster Recovery Serviceguard Solutions Using Metrocluster with Continuous Access XP P9000 for Linux B.12.00.00

# run the raidscan command on ftsys1a or ftsys2a that is connected to the
# remote XP array.
# The HORCM_LDEV parameters are used to describe
# stable LDEV# and Serial# as another way of HORCM_DEV used 'port#,Target-ID,LUN'.
# [Note]:
# This feature depends on the micro version of RAID or kind of RAID.
# <dev_group>
# This parameter is used to define the device group name for paired logical
# volumes. The device group name is used by all Raid Manager commands for
# accessing these paired logical volumes.
# <dev_name>
# This parameter is used to define the names of the paired logical volumes
# in the device group.
# <Serial#>
# This parameter is used to describe the Serial number of RAID box.
# <CU:LDEV(LDEV#)>
# This parameter is used to describe the LDEV number in the RAID box,
# This parameter is used to describe the LDEV number in the RAID box,
HORCM_LDEV
#dev_group dev_name Serial# CU:LDEV(LDEV#) MU#
pkgA pkgA_index 60095 01:04 0
pkgA pkgA_logs 60095 01:05 0
pkgB pkgB_d1 60095 01:06 0
pkgC pkgC_d1 60095 01:07 0
pkgD pkgD_d1 60095 01:08 0
HORCM_INST
#dev_group ip_address service
pkgA ftsys1 horcm0
pkgB ftsys1 horcm0
pkgC ftsys1 horcm0
pkgD ftsys1 horcm0
Sample RAID Manager configuration file for the Virtual Command Device
This section includes a sample RAID Manager configuration file for the virtual command device.
For this sample, following are the configuration details:
ftsys1 and ftsys2 are part of primary site
ftsys1a and ftsys2a are part of recovery site
horcm0 is the local array Raid manager
10.0.0.1 is the IP address of the service processor
31001 is the UDP communication port number
The following is an example of a RAID manager configuration file for one node (ftsys1).
## horcm0.conf.ftsys1- This is an example Raid Manager configuration
# file for node ftsys1.Note that this configuration file is for Raid
# Manager instance 0, which can be determined by the "0" in the filename
# "horcm0.conf".
# Whenever this configuration file is changed, you must stop and restart
# the instance of Raid Manager. This can be done using the following commands:
# horcmshutdown.sh <instance>
# horcmstart.sh <instance>
# After restarting the Raid Manager instance, you must confirm that there
# are no configuration errors reported by running the pairdisplay command
# with the "-c" option.
HORCM_MON
#ip_address service poll_interval(10ms) timeout(10ms)
ftsys1 horcm0 1000 3000
HORCM_CMD
\\.\IPCMD-10.0.0.1-31001
HORCM_DEV
#dev_group dev_name port# TargetID LUN#
68 Sample configuration files for Metrocluster with Continuous Access XP P9000 for Linux B.01.00.00