HP StorageWorks EVA VDS and VSS Hardware Providers 5.02.00 for Windows Server 2003 Release Notes

To install and configure the HP P6000 VSS hardware provider on cluster nodes, you must have
installed the Microsoft Distributed Transaction Coordinator, and it must be running. Some applic-
ations, such as in Microsoft Exchange and SQL clusters, required a MSDTC cluster resource to be
created as part of the application setup. In this case no additional steps are required to install the
HP P6000 VSS hardware provider. To install the HP P6000 VSS hardware provider on application
server cluster nodes that do not already have MSDTC installed and running, see Microsoft TechNet
article, "How to Install the Microsoft Distributed Transaction Coordinator in a Windows Server
2003 Server Cluster." The article is located at the following URL: http://support.microsoft.com/
kb/301600.
Installation Instructions
If you are installing the hardware providers for the first time, proceed with the installation normally.
If the currently installed version of the hardware provider is older than version 4.01.02, you will need
to remove it manually (later versions of the hardware provider are removed automatically by the
hardware provider installation program). Before removing the hardware providers, issue a net stop
VSS and/or a net stop VDS command from the command line.
There are three installers for the hardware providers:
HP_StorageWorks_VDS_VSS_Hardware_Provider_P6000_v4_06_00_x86.exe
HP_StorageWorks_VDS_VSS_Hardware_Provider_P6000_v4_06_00_x64.exe
HP_StorageWorks_VDS_VSS_Hardware_Provider_P6000_v4_06_00_ia64.exe
For installation instructions see the HP StorageWorks Hardware Providers for VDS/VSS installation
guide (5697-0804, February 2011). The guide is included with the installation software package
and provides detailed installation and configuration instructions.
Compatibility/Interoperability
Only one dedicated Command View workstation is supported within the SAN configuration which
manages VDS/VSS storage resources.
If the P6000 VSS hardware provider and Command View EVA are present on the same server,
do not include the drive letter or mount point where the Command View EVA software is located
as part of a shadow copy volume set. For example, if the P6000 VSS hardware provider and
Command View EVA are on drive D, do not include drive D with an P6000 LUN in a shadow
copy set. Doing so causes the P6000 VSS hardware provider to time out due to conflict with
Command View logging on this drive.
Mirrorclones are supported with microcode version XCS 6.11 or later.
Version 4.04.00 of the HP StorageWorks Enterprise Virtual Array Hardware Providers software
is the last version that will support the HP StorageWorks 3000 EVA Storage System and the HP
StorageWorks 5000 EVA Storage System.
The hardware providers do not support vdisks created under a folder that is nested within 40 or
more recursively nested folders.
After a LUN shrink operation using the VDS hardware provider, you must perform the Subsystem
Renumerate operation to update the LUN properties.
VSS Hardware Provider
Supports VMware VM (Shadow Copy creation only).
Supports Hyper-V Host and Guest O/S (Guest O/S - Shadow Copy creation only).
HP StorageWorks P6000 VDS and VSS Hardware Providers 4.06.00 for Windows Server 2003
Release Notes 5