HP StorageWorks XP VDS and VSS Hardware Providers 5.01.00 for Windows Server 2003 release notes (T1634-96090, December 2009)
Enhancements
Support is provided for the following:
• VSS:
• Business Copy of Continuous Access Volume
• Hyper-V Guest O/S (Guest O/S - Shadow Copy creation only)
• VMware VM (Shadow Copy creation only)
• VDS:
• Hyper-V Guest O/S. The unmask or present operation of a LUN to the local host is not supported
on a Hyper-V Guest OS.
• VMware VM. The unmask or present operation of a LUN to the local host is not supported on
a VMware VM.
NOTE:
HP StorageWorks XP VDS and VSS Hardware Providers is supported on VMware ESX Server 3.5
Update 4 and VMware ESX Server 4.0 and later.
Fixes
None
Prerequisites
• XP1024 disk arrays:
Microcode: 21.14.37–00/00 (minimum level)
HP StorageWorks RAID Manager Library 1.12.04 (or later)
HP StorageWorks XP Business Copy
HP StorageWorks XP Array Manager Software
Set system mode 140
• XP10000 and XP12000 disk arrays:
Microcode: 50.09.41.00/00 (minimum level)
HP StorageWorks RAID Manager Library 1.12.04 (or later)
HP StorageWorks XP Business Copy
HP StorageWorks LUN Configuration and Security Manager XP
Set system mode 140
• XP24000 and XP20000 disk arrays:
Microcode: 60-02-04-00/00 (minimum level)
HP StorageWorks RAID Manager Library 1.12.04 (or later)
HP StorageWorks XP Business Copy
HP StorageWorks XP Array Manager Software
Set system mode 140
4