HP 2000 G2 Modular Smart Array Controller Firmware M113R10 Release Notes (508849-014, February 2012)

Issue: Some entries in the SMU and CLI are not localized properly for all languages.
Workaround: HP is continually updating localized content.
Issue: Some configuration changes under heavy I/O may return a communication error.
Workaround: Retry configuration changes during a period of lower I/O.
Issue: Some cached data in the browser may not be updated while navigating through the SMU.
Workaround: Press CTR + F5 to refresh or log out and back into the SMU.
Issue: The tree view for a vdisk in SMU may not function properly.
Workaround: Click the ++ symbol at the top of the tree view. This refreshes the screen and enables the tree view.
Issue: In single controller mode, some event log descriptions can indicate a second controller.
Workaround: These messages can be safely ignored.
Issue: During drive firmware upgrade, all volumes are taken offline to preserve data integrity.
Workaround: Plan drive firmware updates during a maintenance window.
Issue: In an HP c-Class BladeSystem environment, VMWare may fail I/O during failover operations.
Workaround: The VMWare kernel parameter ResetOnFailover must be set to 0 in order for array failover to work
properly.
Issue: The serial number for a volume returned by the SMU and CLI does not match the serial number returned by VPD
data.
Workaround: Serial numbers are shown in different formats. The last 16 digits of the serial number are unique for each
volume and match between the CLI, SMU, and VPD data.
Issue: You can not create volumes for OpenVMS using the Provisioning Wizard or Create Volume Set pages of the SMU.
Workaround: Volumes for OpenVMS may only be created using the Create Volume page of the SMU.
Issue: If an error occurs before the provisioning wizard is complete then partial commits of configuration changes will
be made. The provisioning wizard cannot be used to complete the configuration changes.
Workaround: Use the Create Volume Set and Default Mapping pages of the SMU to complete the configuration.
Supersedes history
Release dateFirmware Version
February 2012M113R11
August 2011M112R14-03
May 2011M112R14-02
October 2010M111R06-07
August 2010M111R06-04
August 2010M111R06
April 2010M110R28-02
March 2010M110R28
December 2009M110R25
Effective date
February 2012
Supersedes history 17