HP 2000 G2 Modular Smart Array Controller Firmware M113R10 Release Notes (508849-014, February 2012)
• HP 2324i G2 Modular Smart Array (HP MSA2324i G2)
• HP 2324sa G2 Modular Smart Array (HP MSA2324sa G2)
Operating systems
Operating systems supported for use with the HP MSA2000 G2 family of products and when installing
the binary firmware package:
• Citrix XenServer HP Enterprise Editions
• HP-UX 11i V2 Integrity, HP9000
• HP-UX 11i V3 Integrity, HP9000
• Microsoft Windows 2003 and 2003 R2 IA32, x64, IA64
• Microsoft Windows Server 2008 and 2008 R2 IA32, x64, IA64 (Standard, Enterprise, Datacenter)
• Microsoft Windows Server 2008 x64 Hyper-V
• OpenVMS 8.3. OpenVMS 8.3-1H1
• Red Hat Enterprise Linux 4 x86, x64, IA64
• Red Hat Enterprise Linux 5 x86, x64, IA64
• Red Hat Virtualization
• SuSE Linux Enterprise Server 9, 10, and 11 x86, x64, IA64
• VMware ESX 3.0.1, 3.0.2, 3.5, 4.0, 5.0 Edition
• Solaris 10 x86, x64
Operating systems supported for use when installing the Smart Component firmware package:
• Microsoft Windows Server 2003 x86, x64, IA64
• Microsoft Windows Server 2008 x86, x64, IA64
• Red Hat Enterprise Linux 4 x86, x64, IA64
• Red Hat Enterprise Linux 5 x86, x64, IA64
• Red Hat Enterprise Linux 6 x64
• SuSE Linux Enterprise Server 10 x86, x64, IA64
Enhancements and fixes
The following enhancements and fixes were incorporated in M113R11:
• Reduced I/O disruption during rescans after drives are hot-plugged.
• Modified the spare drive policy to look for spares in the same enclosure as the failed drive before
searching for spares elsewhere in the system.
• Improved drive error handling.
• Improved the notifications for newer drive models.
• Service protocols are now password protected.
• Improved support for 2TB and larger drives.
• Improved RAID10 performance.
• Improved error reporting for super capacitor events. A failure event is now generated after 10
retries.
• Improved I/O performance during a drive rebuild.
• Enhanced time zone options for -4.30, +3.30, and +13:00.