HP OneView 1.10 Release Notes

ResolutionSymptom
Update the firmware on the HP ProLiant G7 blade, including
the HP NC542m to the latest HP Service Pack for ProLiant,
HP ProLiant G7 server blades with HP NC542m Dual
Port Flex-10 10GbE BLc adapter results in 0 virtual ports
reported due to firmware below the minimum. physically remove the blade from the enclosure, delete the
server hardware type, and then re-insert the server blade.
To manually align the power state of the server hardware
and HP OneView, perform a Refresh action from the Server
HP ProLiant G7 server blade does not reflect correct
power state in HP OneView, if controlling power outside
of HP OneView. Hardware screen. In general, HP recommends using HP
OneView to control power to the server hardware, which
avoids this misalignment.
Update the firmware on the HP ProLiant G7 blade, including
the HP NC55x to the latest HP Service Pack for ProLiant,
HP ProLiant G7 server blade will not boot from SAN
because the FlexFabric NC55x adapter Converged
physically remove the server blade from the enclosure, delete
the server hardware type, and then re-insert the server blade.
Network Adapter firmware is below the supported
minimum.
Boot the server through POST (power on self-test), enter RBSU,
exit RBSU, power off the server, and apply the profile again.
HP ProLiant G7 server blade has incorrect boot controller
order if the profile is applied after resetting the BIOS to
factory defaults via the RBSU (ROM Based Setup Utility
F9).
If it is necessary to use the Java plug-in console, update the
iLO firmware by applying a server profile that specifies a
Selecting ActionsLaunch console and attempting to use
the iLO Java plug-in console for G7 server hardware
firmware baseline with the default Service Pack for ProLiant,with iLO versions 1.61 or older, or Gen8 server
or one with a minimum level of iLO3 version 1.65 for G7
servers or iLO4 version 1.40 for Gen8 servers.
hardware with iLO versions 1.30 or older, results in a
security exception error message indicating a missing
permissions attribute in the manifest.
Use the Force remove enclosure option to remove the
enclosure.
Removing an enclosure fails to remove the interconnects
or logical interconnect.
Check the interconnect uplink port status to detect any
configuration errors at the network level. Verify that the
physical cabling matches the configuration.
An incorrect logical interconnect or logical interconnect
group configuration or cabling issue can result in storage
paths from a server profile that are not reachable by the
server yet have a healthy status.
Select ActionsRefresh from the Enclosures screen.In logical interconnect configurations with Cisco Fabric
Extender (FEX) modules, an action results in an alert on
the Enclosures screen that HP OneView is no longer
controlling this enclosure.
Manually set all LUN values to be new and unique.LUN validation fails in server profile SAN storage
configurations.
Perform the swap with two profile edits, saving the profile
after each step:
Error stating that the desired LUN is in use while swaping
two manually-configured LUNs between two SAN storage
volumes attached to a server profile.
1. Temporarily configure each of the two volumes to use
unused LUNs.
2. Configure the two volumes to use the desired LUNs.
Use the auto LUN option or specify a unique LUN value that
is not already in use for that server.
Server profile operations with SAN storage result in an
alert indicating an issue with storage paths.
Refresh the screen.Internal Server Error when selecting
EnclosuresUpdate firmware.
14 Troubleshooting