HP OneView REST API Reference

enclosures
enclosures.html[10/17/2013 10:35:21 AM]
type: string
deviceType: description: When discovered via an HP Intelligent Power Distribution
Unit (iPDU), this is the management processor type of
the attached resource:iLO, APM Chassis, BladeSystem,
Storage, Networking, or Server-Other.
readonly: true
type: string
maxPwrConsumed: description: The maximum power consumed by the device in watts.
This value is usedfor capacity/consumption analysis and
should represent an accurate upper-boundon power
consumption.
minimum: 0
type: integer
ipv4Address: description: The IPv4 address of the management processor for the
device.
type: string
searchable: true
model: description: The model information or product name.
required: true
type: string
height: description: The height of the unmanaged device in U-slots.
type: integer
type: description: Identifies the resource type. This field must be set to
'UnmanagedDevice'.
type: string
id: description: The internal identifier of the resource.
readonly: true
required: true
type: string
uuid: description: The universally unique identifier of the resource.
readonly: true
type: string
firmwareBaselineUri: description: The URI of the firmware baseline to apply to the enclosure
type: string
enclosureUri: description: The URI for an enclosure that was previously added. When re-adding an
enclosure, either enclosure URI or hostname can be used to identify the
enclosure. If both are specified, hostname will be used and enclosure URI will be
ignored.
type: string