HP OneView REST API Reference

server-hardware
server-hardware.html[10/17/2013 10:35:23 AM]
used by the device MUST NOT exceed the reported Calibrated Maximum Power by greater than 1%. 6. The
Calibrated Maximum Power SHOULD NOT exceed the actual maximum power that the device is capable of
using by more than 5%.
type: integer
required: true
psuList: description: The list of configuration data for each power supply of the device.
type: array
Items
capacity: description: The size of the power supply in Watts.
type: integer
psuId: description: A small integer identifying the slot or bay number of the power supply starting at one
(1).
type: integer
inputVoltage: description: The line voltage (input) to the power supply (sampled or nominal).
type: integer
side: description: The logical power delivery grouping of the power supply. In a known non-redundant
configuration, all power supplies should be considered on side A. In a known AC-
redundant configuration, the 2 sets of redundant power supplies should be identified
as side A/B groupings. For an AC_REDUNDNAT C-Class BladeSystem slot 1,2,3 is
on Side B (right from the front), and 4,5,6 are on Side A (left from the front). If there is
no inherent side-ness, then the side will be Dynamic.
type: string
enum: Unspecified
A
B
Dynamic
powerType: description: The type of input power (AC or DC) of the power supply.
type: string
enum: Unknown
AC
DC
height: description: The height of the device in u-slots (-1 for unspecified).
type: integer
required: true
rackId: description: The GUID of the containing rack if available; otherwise null.
type: string
uSlot: description: The top-u-slot number of the device in the associated rack if available; -1 otherwise.
type: integer
required: true
rackName: description: The rack name associated to this device (null for unspecified).
type: string
relativeOrder: description: The relative order of a resource in a Rack when slot information cannot be discovered and is not yet
configured. This information is derived from the management link cable connections in a BladeSystem
enclosure. The values increase from top to bottom, the lowest number (one at top of rack) to highest
number (bottom of rack). A value of -1 indicates unspecified.
type: integer
required: true
licenseRequirement: description: Reflects any known missing license requirement that prevents access to environmental monitoring features
of the resource. If the value is None, then there are no known issues preventing access to environmental
monitoring features of the resource. If the value is iLOAdvanced, then the server hardware must have an
iLOAdvanced license applied to environmental monitoring features. If the value is OneView, then it indicates
that there are insufficient HP OneView licenses available to the appliance to enable environmental
management features on the resource.
type: string