HP OneView REST API Reference

logical-interconnect-groups
logical-interconnect-groups.html[10/17/2013 10:35:26 AM]
maximum: 30
minimum: 1
name: description: A user friendly name
type: string
readonly: true
created: description: Date and time when the resource was created
pattern: [1-2][0-9][0-9][0-9]-([0-1][0-9])-[0-3][0-9]T[0-2][0-9]:[0-5][0-9]:[0-5][0-9](.[0-9][0-9][0-9])?Z
type: string
format: YYYY-MM-DDThh:mm:ss.sssZ
enableNetworkLoopProtection: description: Enables or disables network loop protection
default: true
type: boolean
enableFastMacCacheFailover: description: This will cause Ethernet packets to be tranmitted on newly-active links.
default: true
type: boolean
uri: description: The canonical URI of the resource
type: string
enableIgmpSnooping: description: Internet Group Management protocol (IGMP) allows modules to monitor the IGMP IP multicast membership activities.
default: false
type: boolean
state: description: Current state of the resource
type: string
eTag: description: Entity tag/version ID of the resource, the same value that is returned in the ETag header on a GET of the resource
type: string
modified: description: Date and time when the resource was last modified
pattern: [1-2][0-9][0-9][0-9]-([0-1][0-9])-[0-3][0-9]T[0-2][0-9]:[0-5][0-9]:[0-5][0-9](.[0-9][0-9][0-9])?Z
type: string
format: YYYY-MM-DDThh:mm:ss.sssZ
dependentResourceUri: description: The URI which the setting will be applied to. This returned value will be either logical interconnect or logical interconnect
template URI.
type: string
readonly: true
category: description: Resource category used for authorizations and resource type groupings
type: string
type: description: Identifies the resource type. This field must be set to 'EthernetInterconnectSettings'.
type: string