HP OneView 1.05 User Guide

27.2 REST API power and temperature monitoring
27.2.1 Update enclosure power capacity settings
To update the enclosure capacity settings, perform a PUT operation that includes only the
calibratedMaxPower attribute. View the enclosure capacity settings attributes by using a GET
operation, edit the calibratedMaxPower attribute, and then perform a PUT operation that
includes only the edited calibratedMaxPower attribute.
Prerequisites
Minimum required session ID privileges: Server administrator
Updating enclosure capacity settings using REST APIs
1. Select an enclosure URI.
GET /rest/enclosures
2. Get the enclosure capacity using the URI from step 1.
GET {enclosure URI}/environmentalConfiguration
3. Edit the enclosure capacity. The only attribute to send in the response body is calibratedMaxPower. Do not
send all attributes from the GET operation.
4. Update the enclosure capacity.
PUT {enclosure URI}/environmentalConfiguration
27.2.2 Update server hardware power capacity settings
To update server hardware capacity settings, perform a PUT operation that includes only the
calibratedMaxPower attribute. View server hardware capacity settings attributes by using a
GET operation, edit the calibratedMaxPower attribute, and then perform a PUT operation that
includes only the edited calibratedMaxPower attribute.
Prerequisites
Minimum required session ID privileges: Server administrator
Updating server hardware capacity settings using REST APIs
1. Select a server hardware URI.
GET /rest/server-hardware
2. Get the current server hardware capacity using the URI from step 1.
GET {server hardware URI}/environmentalConfiguration
3. Edit the server hardware capacity. The only attribute to send in the response body is calibratedMaxPower. Do
not send all attributes from the GET operation.
4. Update the server hardware capacity.
PUT {server hardware URI}/environmentalConfiguration
202 Monitoring power and temperature