HP OneView 1.05 User Guide

Table 14 SAN A and SAN B Fibre Channel network configurations
NotesValueConfiguration attribute
Fibre ChannelType
Choose Fabric attach for Fibre Channel networks that connect to SAN
switches in the data center.
Fabric attachFabric type
This is the default value displayed on the Create network screen.2.5 Gb/sPreferred bandwidth
This is the default value displayed on the Create network screen.8 Gb/sMaximum bandwidth
This is the default value displayed on the Create network screen.AutoUplink speed
This is the default value displayed on the Create network screen.AutoLogin redistribution
This is the default value displayed on the Create network screen.30 secondsLink stability time
Fibre Channel networks directly attached to the 3PAR Storage System (Flat SAN)
The sample data center has a 3PAR Storage System that is connected directly to an enclosure. This
is called a Flat SAN or Direct attach network configuration. To see a graphical representation of
the configuration, see Figure 17 (page 255).
The names of the Direct attach Fibre Channel networks follow:
FlatSAN A
FlatSAN B
Table 15 FlatSAN A and FlatSAN B Fibre Channel network configurations
NotesValueConfiguration attribute
Fibre ChannelType
Choose Direct attach for Fibre Channel networks that connect to the 3PAR
storage system.
Direct attachFabric type
This is the default value displayed on the Create network screen.2.5 Gb/sPreferred bandwidth
This is the default value displayed on the Create network screen.8 Gb/sMaximum bandwidth
This is the default value displayed on the Create network screen.AutoUplink speed
This is the default value displayed on the Create network screen.AutoLogin redistribution
This is the default value displayed on the Create network screen.30 secondsLink stability time
254 Step by step: Configuring an example data center using HP OneView