HP OneView 1.05 Release Notes

Table 1 Troubleshooting: Issues and resolutions (continued)
ResolutionIssue
Configure HP 3PAR Direct attach array ports with:
Connection Mode = Host, Connection Type =
Point.
Incorrect configuration of the host port on the HP 3PAR
Storage System when attached to the HP VC FlexFabric
module via direct attach FC network can cause intermittent
connectivity on the FlexFabric module.
Try again, the second attempt will succeed.First attempt to manually redistribute logins has no effect.
Use the zoom slider.Some versions of Microsoft Internet Explorer obscure the
3D data center zoom out button.
Use the Data CentersAdd button instead of the .Add+
button.
Adding multiple data centers with the Add+ button results
in layout artifacts that can result in errors.
Update the firmware on the HP ProLiant G7 blade,
including the HP NC542m to the latest HP Service Pack
HP ProLiant G7 server blades with HP NC542m Dual Port
Flex-10 10GbE BLc adapter results in 0 virtual ports
reported due to firmware below the minimum. for ProLiant, physically remove the blade from the
enclosure, delete the server hardware type, and then
re-insert the server blade.
To manually align the power state of the server hardware
and HP OneView, perform a Refresh action from the Server
HP ProLiant G7 server blade does not reflect correct power
state in HP OneView, if controlling power outside of HP
OneView. Hardware screen. In general, HP recommends using HP
OneView to control power to the server hardware, which
avoids this misalignment.
Update the firmware on the HP ProLiant G7 blade,
including the HP NC55x to the latest HP Service Pack for
HP ProLiant G7 server blade will not boot from SAN
because the FlexFabric NC55x adapter Converged Network
Adapter firmware is below the supported minimum. ProLiant, physically remove the server blade from the
enclosure, delete the server hardware type, and then
re-insert the server blade.
Boot the server through POST (power on self-test), enter
RBSU, exit RBSU, power off the server, and apply the
profile again.
HP ProLiant G7 server blade has incorrect boot controller
order if the profile is applied after resetting the BIOS to
factory defaults via the RBSU (ROM Based Setup Utility
F9).
10 Troubleshooting