fcConnUnitPor
tModuleType
INTEGER If the port is not installed,
return gbicNotInstalled(8).
Otherwise return
smallFormFactor(9).
R The module type of the port
connector. This object refers
to the hardware
implementation of the port.
The embedded value (4)
means ‘fixed’ (for example,
oneXnine).
The values are defined as
follows: unknown (1), other
(2), gbic (3), embedded (4),
glm(5), gbicSerialId (6),
gbicNoSerialId (7),
gbicNotInstalled (8),
smallFormFactor (9).
FcConnUnitPo
rtWwn
FcNameI
d
World Wide Name of the
port.
R The World Wide Name of
the port. If applicable;
otherwise empty string.
FcConnUnitPo
rtFCId
OCTET
STRING
(SIZE(3))
If it’s F-port, return fabric
address of the node in form
of [domain, area, node].
(Supported by Login Server)
If it’s E-port, return
left-adjusted domain ID of
the switch.
R This is the assigned Fibre
Channel ID of this port. This
value is expected to be a Big
Endian value of 24 bits. If this
is loop, then it is the ALPA
that is connected. If this is an
eport, then it will only contain
the domain ID left justified,
zero filled. If this port does
not have a Fibre Channel
address, return all bits set to
1.
FcConnUnitPo
rtSerialNoSn
SnmpAd
minString
Not applicable. R The serial number
identification of the unit (for
example, for a GBIC). If this
is not applicable, return a
zero-length
string.
FcConnUnitPo
rtRevision
SnmpAd
minString
Not applicable. R The port revision (for
example, for a GBIC).
FcConnUnitPo
rtVendor
SnmpAd
minString
Not applicable. R The port vendor (for example,
for a GBIC).
FcConnUnitPo
rtSpeed
Gauge32 Return 100000 kilobytes
for 1 Gb/s switches and
200000 kilobytes for 2
Gb/s switches.
R The speed of the port in
kilobytes per second.