FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
111SNMP Reference for Directors and Edge Switches
*fcConnUnitE
ventIndex
(continued)
(continued from previous cell)
The index value is an
incrementing integer starting
from one every time there is a
table reset. On table reset, all
contents are emptied and all
indices are set to zero. When
an event is added to the table,
the event is assigned the next
higher integer value than the
last item entered into the table.
If the index value reaches its
maximum value, the next item
entered will cause the index
value to roll over and start at
one again.
FcConnUnitRE
ventTime
DisplayStrin
g
(SIZE (15))
The time when the event
occurred.
R This is the real time when the
event occurred. It has the
following format.
DDMMYYYY HHMMSS
DD = day number, MM =
month number, YYYY = year
number, HH = hour number,
MM= minute number, SS =
seconds number
If not applicable, return a NULL
string.
FcConnUnitSE
ventTime
TimeTicks Translated from
fcConnUnitREventTime.
R This is the sysuptime timestamp
when the event occurred.
FcConnUnitEv
entSeverity
FcEventSeve
rity
The mapping from
switch event severity
level to FcEventServerity:
SWITCH
MIB
informational
info(8)
minor
error(5)
major
critical(4)
severe
emergency(2)
R The event severity level:
unknown (1)
emergency (2)
alert (3)
critical (4)
error (5)
warning (6)
notify (7)
info (8)
debug (9)
mark (10)