FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
113SNMP Reference for Directors and Edge Switches
This table is accessed either directly if the management software has an index
value or via GetNexts. The value of the indexes are not required to be contiguous.
Each entry created in this table will be assigned an index. This relationship is kept
persistent until the entry is removed from the table or the system is reset. The total
number of entries are defined by the size of the table.
Note: For EOS firmware: A reset or firmware load will cause this table to be
regenerated from the persistent login database – table indices will most likely be
associated with different entries after the reset.
FA MIB
Object
Name
Type Product Mapping
Acces
s
Description
*fcConnUnitLi
nkIndex
Unsigned
32
A link index. R This value is used to create a
unique value for each entry
in the link table with the
same fcConnUnitId. The
value can only be reused if it
is not currently in use and the
value is the next candidate to
be used. This value is
allowed to wrap at the
highest value represented by
the number of bits. This value
is reset to zero when the
system is reset and the first
value to be used is 1.
FcConnUnitLin
kNodeIdX
OCTET
STRING
(SIZE(16))
The WWN of the local
fcConnUnit is returned. This
information is available for
both E and F_Ports
R The node WWN of the unit
at one end of the link. If the
node WWN is unknown and
the node is an fcConnUnit in
the responding agent then
the value of this object
must
BE equal to its fcConnUnitId.
FcConnUnitLin
kPortNumber
X
Integer32 The fcConnUnit’s local port
number is returned. This
information is available for
both E and F_Ports.
R The port number on the unit
specified by
fcConnUnitLinkNodeIdX if
known, otherwise –1. If the
value is non-negative then it
will be equal to
fcConnUnitPortPhysicalNum
ber.