FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
115SNMP Reference for Directors and Edge Switches
FcConnUnitLin
kAgentPortY
Unsigned
32
R The IP port number for the
agent. This is provided in
case the agent is at a
non-standard SNMP port.
FcConnUnitLin
kUnitTypeY
FcUnitTyp
e
If it’s E port, return switch
(4). Otherwise return RNID
type Y.
R Type of the FC connectivity
unit as defined in
fcConnUnitType.
FcConnUnitLin
kConnIdY
OCTET
STRING
(SIZE(3))
For F_Ports, return Fibre
Channel Address. For
E_Ports, return left adjusted
domainId of the switch.
RThis is the Fibre Channel ID
of this port. If the connectivity
unit is a switch, this is
expected to be a 24-bit Big
Endian value. If this is loop,
then it is the ALPA that is
connected. If this is an
E_Port, then it will only
contain the domain ID. If not
any of those, unknown or
cascaded loop, return all bits
set to 1.