FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
135SNMP Reference for Directors and Edge Switches
fcEosPortConfi
gSpeed
INTEGER PCP R The configured port speed. The values are
defined as follows: one-gig (1), two-gig
(2), negotiate (3).
fcEosPortOpS
peed
PCP R The current operating speed of the port.
The values are defined as follows:
unknown (1), one-gig (2), two-gig (3),
negotiate (4).
fcEosPortConfi
gType
INTEGER R/W The configured port type:
gPort (1),
fPort (2),
ePort (3),
flPort (4),
fxPort (5),
gxPort (6)
fcEosPortOpTy
pe
INTEGER R The operating port type:
unknown (1),
ePort (2),
fPort (3),
flPort (4)
fcEosPortALPA
Index
LoopPortALPA R The ALPA-Index bit map that identifies the
list of ALPA's associated with the FL_port.
Only applicable for flPorts.
fcEosPortFAN TruthValue R/W This object identifies/configures if the port
supports Fabric Address Notification
mode. Only applicable for flPorts.
fcEosPortTxW
ords32
Counter PSCC R A 32-bit counter for the number of words
within frames that the port has transmitted.
(Primitive signals and primitive sequence
are not included.)
fcEosPortRxW
ords32
Counter PSCC R A 32-bit counter for the number of words
within frames that the port has received.
(Primitive signals and primitive sequence
are not included.)
fcEosPortTxFra
mes32
Counter PSCC R A 32-bit counter for the number of (Fibre
Channel) frames that the port has
transmitted.
fcEosPortRxFr
ames32
Counter PSCC R A 32-bit counter for the number of (Fibre
Channel) frames that the port has
received.