FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
148 SNMP Reference for Directors and Edge Switches
The alert symbol is displayed on the corresponding port card in the Hardware
View, and next to the specific port in the Port Card Detailed View, and in the Alert
column of the Port List View. It indicates that a corrective action is required to
return the port back to a normal operating state.
** connUnitPortState (1)unknown, (2)online, (3)offline, (4)bypassed
connUnitPortStatus (1)unknown, (2)unused, (3)ok, (4)warning, (5)failure,
(6)notparticipating, (7)initializing, (8)bypassed
connUnitPortHWState (1)unknown, (2)failed, (3)bypassed, (4)active,
(5)loopback, (6)txfault, (7)noMedia, (8)linkDown
*** fcFxPortPhysOperStatus (1)online, (2)offline, (3)testing, (4)link-failure
STAT_IN
ACTIVE
Inactive Yellow
Triangle
offline(
3)
warnin
g(4)
active(
4)
offline(2
)
The ‘Inactive
Port State
signifies a
port is not
able to come
online due to
a
configuration
conflict
(either
software or
hardware) on
the switch.
The intention
of the
‘Inactive’ port
state is to
provide user
notification
when a
configuration
conflict is
preventing a
port from
coming
online. One
of the
reasons for
this state is
an
unlicensed
port.