FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
27SNMP Reference for Directors and Edge Switches
Enterprise-specific FRU Status Change Trap
This trap is sent for each FRU that has a status change. There is one variable
binding as follows:
Binding OID Value
1 1.3.6.1.4.1.289.2.1.1.2.2.1.1.3.fru_code.fru_pos
fcEosFruStatus.fru_code.fru_pos
Where fru_code has one of the following values:
0x01, Backplane
0x02, Control Processor card
0x03, Serial Crossbar
0x04, Shasta 32 center fan module
0x05, Fan module
0x06, Power supply module
0x07, Reserved
0x08, Longwave, Single-Mode, LC connector, 1 Gig (Port card)
0x09, Shortwave, Multi-Mode, LC connector, 1 Gig (Port card)
0x0A, Mixed, LC connector, 1 Gig (Port card)
0x0B, SFO pluggable, 1 Gig
0x0C, SFO pluggable, 2 Gig
0x0D, Longwave, Single-Mode, MT-RJ connector, 1 Gig
0x0E, Shortwave, Multi-Mode, MT-RJ connector, 1 Gig
0x0F, Mixed, MT-RJ connector, 1 Gig
0x10, F-Port, internal, 1 Gig
And where fru_pos is a number specific to each possible FRU
position, which varies from product to product. For example, on a
Director 2/140 there are three fans numbered 1 to 3.
New status value.
See definition for
fcEosFruStatus” on
page 133.