FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
37SNMP Reference for Directors and Edge Switches
System Group
MIB-2
Object
Name
Type Access Description
sysDescr DisplayString(0..255) R A textual description of the entity. This value
should include the full name and version
identification of the system's hardware type,
software operating-system, and networking
software. It is mandatory that this only
contain printable ASCII characters
sysObjectID Object Identifier R The vendor’s authoritative identification of the
network management subsystem contained in
the entity. This value is allocated within the
SMI enterprises subtree (1.3.6.1.4.1) and
provides an easy and unambiguous means
for determining ‘what kind of box’ is being
managed. For example, if vendor ‘Flintstones,
Inc.’ was assigned the subtree
1.3.6.1.4.1.4242, it could assign the
identifier 1.3.6.1.4.1.4242.1.1 to its ‘Fred
Router’
sysUpTime TimeTicks R The time (in hundredths of a second) since
the network management portion of the
system was last re-initialized
sysContact DisplayString (0..255) R The textual identification of the contact person
for this managed node, together with
information on how to contact this person