FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
74 SNMP Reference for Directors and Edge Switches
FcFxPortPhysAdmi
nStatus
INTEGER PCP, FPM R/W The desired state of the FxPort. A
management station may place the
FxPort in a desired state by setting this
object accordingly. The testing(3) state
indicates that no operational frames can
be passed. When a Fabric Element
initializes, all FxPort start with
fcFxPortPhysAdminStatus in the
offline(2) state. As the result of either
explicit management action or per
configuration information accessible by
the Fabric Element,
fcFxPortPhysAdminStatus is then
changed to either the online(1) or
testing(3) states, or remains in the offline
state. The values are defined as follows:
online(1) – place port online, offline(2) –
take port offline, testing (3).
This MIB variable is maintained by both
the portState, ps*, defined in FPM and
the PORT_BLOCKED_STATE, pstate*,
defined in PCP. The psNotInstalled
shows that the port does not exist. The
psIntDiags and psExtLoop indicate the
testing(3) state. The pstateUNBLOCKD
and pstateBLOCKD indicate the
online(1) and offline(2) respectively.
If the port cannot be set to testing
because it is inactive or in a failed state,
the return value will be
resource_unavailable(13).