FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
95SNMP Reference for Directors and Edge Switches
FcConnUnitC
ontrol
INTEGER Always return
unknown (1) on
read operation.
ResetConnUnit
WarmStart (4),
offlineConnUnit
(5), and
onlineConnUnit
(6) will be
supported by
PCP.
ResetConnUnit
WarmStart (4)
indicates IPL on
the switch is
performed.
ResetConnUnitC
oldStart (3) is
not supported.
R/W This object is used to control the
addressed connectivity unit.
NOTE: ‘ColdStart’ and ‘WarmStart
are as defined in mib-2 and are not
meant to be a factory reset.
ResetConnUnitColdStart: the
addressed unit performs a
‘ColdStart’ reset.
ResetConnUnitWarmStart: the
addressed unit performs a
‘WarmStart’ reset.
OfflineConnUnit: the addressed unit
puts itself into an implementation
dependant ‘offline’ state. In general,
if a unit is in an offline state, it
cannot be used to perform
meaningful Fibre Channel work.
OnlineConnUnit: the addressed unit
puts itself into an implementation
dependant ‘online’ state. In general,
if a unit is in an online state, it is
capable of performing meaningful
Fibre Channel work.
NOTE: Each implementation may
chose not to support SNMP Set
operations for any or all of these
values. For Sets specifying varbinds
for instances of this object and
values not supported by a given
implementation, the agent will return
the SNMP WrongValue PDU error
code.
The values are defined as follows:
unknown (1), invalid (2),
resetConnUnitColdStart (3),
resetConnUnitWarmStart (4),
offlineConnUnit (5), onlineConnUnit