FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
96 SNMP Reference for Directors and Edge Switches
FcConnUnitC
ontact
SnmpAdminSt
ring
Contact
information for
this connectivity
unit.
Writable and
persistent across
IPL.
R/W Contact information for this
connectivity unit. The contact
information is intended to facilitate
contacting someone in case of
problems, questions, etc. (for
example, the help desk internal to a
company).
FcConnUnitLo
cation
SnmpAdminSt
ring
The physical
location of the
switch.
Writable and
persistent across
IPL.
R/W Location information for this
connectivity unit.
FcConnUnitEv
entFilter
FcEventSeverit
y
Writable and it’s
set to the Default
value of info(8)
after IPL.
R/W This value defines the event severity
that will be logged by this
connectivity unit. All events of
severity less than or equal to
fcConnUnitEventFilter are logged in
the fcConnUnitEventTable.
FcConnUnitN
umEvents
Unsigned32 Number of
events in the
fcConnUnitEvent
Table. It’s
always <= 200,
the maximum
size of the event
table.
R Number of events currently in the
fcConnUnitEventTable.
FcConnUnitM
axEvents
Unsigned32 200. R Max number of events that can be
recorded at any one time in the
fcConnUnitEventTable.
FcConnUnitEv
entCurrID
Unsigned32 The current
event index is
used as the last
used event id.
R The last used event id
(fcConnUnitEventIndex) recorded in
the fcConnUnitEventTable. When no
events are presently recorded in the
fcConnUnitEventTable, the value of
this object
must
be zero.