FW V06.XX/HAFM SW V08.02.00 HP StorageWorks HA-Fabric Manager Appliance Installation Guide (AA-RU5FB-TE, July 2004)

Chapter 2. Installation
2. The depth of th
e equipment cabinet determines if the long rear mounting bracket or short
rear mounting bracket is used.
a. Using a tape measure (provided by installation personnel), measure and record
the depth of the left side of the cabinet from the inside of the front vertical
rack-mounting standard to the inside of the rear vertical rack-mounting standard.
b. Measure and record the depth of the right side of the cabinet from the inside of the
front vertical rack-mounting standard to the inside of the rear vertical rack-mounting
standard.
3. Using a #2 Phillips screwdriver and eight (8) of the ten pan-head Phillips screws (#10
x 1/2) and, if you are installing the server in an HP 9000, 10000 or 11000 rack, eight
(8) square alignment washers, attach four (4) three-hole bar nuts to the rack-mounting
standardsasfollows:
a. Align each three-hole bar nut with the rack-mounting standard as shown in Figure
2-1. Ensure each bar nut is mounted with the narrow side (drilled holes-to-edge
side) facing the inside of the cabinet.
Figure 2.1. Three-Hole Bar Nut Alignment
Note
Ensure the bar nut screw washers to do not overlap the inside edges of the rack-mounting
standards and mounting brack ets. W asher overlap may interfere with slide rail operation.
24
hp StorageWorks HA-Fabric Ma nager Appliance Installation
Guide