FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
133SNMP Reference for Directors and Edge Switches
Port Table (Port Group)
fcEosFruStatus INTEGER SNMP R This object identifies the operational status
of the module. The unknown(0) state
indicates that no information is available
for the FRU, which may happen when no
FRU is installed; The active(1) state
indicates that the current module is active;
The backup(2) state indicates that the back
up module is used; The update-busy (3)
state indicates that the module is in the
updating process; The failed(4) state
indicates that the current module is failed.
fcEosFruPartN
umber
DisplayString
(SIZE (0..64))
McK
DEV-TBL
R The part number of the module. For the fan
FRU, the returned value is NULL.
fcEosFruSerial
Number
DisplayString
(SIZE (0..64))
McK
DEV-TBL
R The serial number of the module. For the
fan FRU, the returned value is NULL.
fcEosFruPower
OnHours
Counter McK
DEV-TBL
R The number of the hours that the FRU has
been in operation. For the fan FRU, the
returned value is NULL.
fcEosFruTestD
ate
DisplayString
(SIZE (0..64))
McK
DEV-TBL
R The final test date of the module. For the fan
FRU, the returned value is NULL.
FCEOS MIB
Object
Name
Type
Provided
By
Access Description
fcEosPortIndex fcEosPortIndex SNMP R The fixed physical port number on the
switch. It ranges from 1 to the number of
physical ports that can be supported in the
switch.
fcEosPortPhySt
ate
fcEosPortPhySt
ate
FPM R The physical state of the port.
fcEosPortOpSt
atus
INTEGER FPM,
SNMP
R The operational status of the port. The
values are defined as follows: online(1),
offline(2), testing(3), and faulty(4). The
online(1) state indicates that user frames
can be passed. See “Port State
Descriptions” on page 143. If the port is
not installed, returns offline(2).