FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
141SNMP Reference for Directors and Edge Switches
Threshold Alert Table
fcEosMember
WWN
ZoneSetState PCP R The WWN name as an 8-character string.
This value is only valid if the member type
is 1, otherwise it will default to 0.
fcEosMember
DomainID
INTEGER PCP R The domain ID. This value is only valid if
the member type is 2, otherwise it will
default to NULL.
fcEosMember
PortNumber
INTEGER PCP R The port number. This value is only valid if
the member type is 2, otherwise it will
default to NULL.
FCEOS MIB
Object
Name
Type
Provided
by
Access Description
fcEosTAIndex INTEGER PCP R This object is used to identify which
threshold has been triggered.
fcEosTAName DisplayString
(SIZE (1..64))
PCP R The threshold alert name.
f c E o s T A S t a t e I N T E G E R P C P R T h e c u r r e n t s t a t e o f t h e t h r e s h o l d . ( e n a b l e d
= 1, disabled = 2)
fcEosTAType INTEGER PCP R The type of the threshold. (throughput = 1,
counter = 2)
fcEosTAPortTy
pe
INTEGER PCP R A threshold can be set on a list of physical
port numbers or on all the ports of the
specified type (ePorts, fPorts). (list = 1,
ePorts = 2, fPorts = 3, flPorts = 4)
fcEosTAPortList fcEosPortList PCP R A bit map that identifies which ports this
threshold alert applies to (only valid if the
Threshold Alert Port Type = list). The left
most bit represents the port 0.
fcEosTAInterva
l
INTEGER PCP R The number of minutes in a threshold alert
interval.
fcEosTATrigger
Value
INTEGER PCP R If the alert type is a Throughput Threshold
Alert, then this is the percent utilization
(1-100) required to trigger an alert. If the
alert type is a Counter Threshold Alert,
then this is the counter delta required to
trigger an alert.