FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
24 SNMP Reference for Directors and Edge Switches
Variable bindings—Serves as the data field of the SNMPv2 PDU. Each
variable binding associates a particular object instance with its current value
(with the exception of Get and GetNext requests, for which the value is
ignored).
Get, GetNext, Inform, Response, Set, and Trap PDUs Contain the Same Fields:
[PDU type | Request ID | Error status | Error index |
Object/Value 1 | Object/Value 2]
For the SNMPv2 trap PDU, the first and second variable bindings contain the
uptime and the trap OID respectively. Following the uptime and trap OID are all
the variable bindings specified in the MIB for that particular trap.
EOS Trap Summary Table
This table shows the different kinds of traps supported by the switch EOS
firmware.
Note: All EOS traps are SNMPv1 format, regardless of MIB definition syntax.
Trap Severity
Sent
because:
MIB Trap OID EOS
HAF
M
Generic
Authentication
Failure
N/A SNMP
request
from an
invalid
community
is received.
RFC-1157 YES NO
Generic Link Up N/A RFC-1157 YES NO
Generic Warm
Start
N/A Software
reset.
RFC-1157 YES NO
Generic Cold
Start
N/A Power up. RFC-1157 YES NO
ES Port Change N/A A change in
port status.
FCEOS 1.3.6.1.4.1.289.1 YES NO
ES Fru Change N/A A change in
FRU status.
FCEOS 1.3.6.1.4.1.289.2 YES NO
ES Invalid
Attachment
N/A Invalid
attachment
to a port.
FCEOS 1.3.6.1.4.1.289.3 YES NO