FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
67SNMP Reference for Directors and Edge Switches
fcFeModuleOper
Status
INTEGER SNMP R This object indicates the operational
status of the module: online(1) – the
module is functioning properly; offline(2)
– the module is not available; testing(3)
– the module is under testing; and
faulty(4) – the module is defective in
some way.
The status is evaluated from
fcFPortPhysOperStatus as following
order.
Testing(3): the module is under testing if
all four ports on the current module are
testing;
faulty(4): the module is defective if any
of the ports on the current module is
faulty.
Online(1): the module is functioning
properly if any of the ports on the
current module is online or testing;
offline(2): the module is not available if
any of the ports on the current module is
offline.
FcFeModuleLastC
hange
TIMETICKS SNMP R This object contains the value of
sysUpTime when the module entered its
current operational status. A value of
zero indicates that the operational status
of the module has not changed since the
agent last restarted.
This is SS_TIM_RD_TICKS(MILLISEC) *
10.
fcFeModuleFxPort
Capacity
FcFeFxPort
Capacity
AS R The number of FxPort that can be
contained within the module. Within
each module, the ports are uniquely
numbered in the range from 1 to
fcFeModuleFxPortCapacity inclusive.
However, the numbers are not required
to be contiguous.
This is
AS_glob.prod_cnfg_ptr->ports_per_mo
dule.
fcFeModuleName FcNameId PCP R The Name_Identifier of the module.
This is the port module World Wide
Name.