HP StorageWorks EVA Hardware Providers administration guide Windows 2003 (T1634-96054, August 2006)

Troubleshooting procedures
The following instructions present typica l problems and solutions.
VDS/VSS HWP will not install
The HP HWP installation works only on the Windows versions listed in the Conguration chapter of this
guide and in the Release Notes supplied with the HP HW P. The installer will n ot install the soft ware on
other versions of Windows.
CV authentication failure
Smart Star
t v7.2 may cause login failures for applications such as HP HWP using the Command View
EVA API. Th
is issue occurs when a ser ver is built using the new SS v7.2 CD and then CV EVA software
is installed.
To resolve this issue, reset the HP Command View API password. This password enables any application
that uses
the HP Command View A PI to authenticate properly. Only a system administrator can run
this utility.
To enable the HP Command View API, follow these steps:
1. Execute t
he following utility/command to change the password:
c:\Program Files\Hewlett-Packard\SANworks\Element Manager for
StorageWorks HSV\Bin\elmsetup.exe -pA:administrator -f
where “ ad
ministrator equ als the password for the HP Comm a nd View API Administrator account.
You can use any password you wish in place of administrator”.
2. In the Services window restart the HP Comma nd View EVA service.
Applica
tions such as HP H W P that use the Command View API should now be able to log into the
API corr
ectly. The new password is for the HP Command View API login only. The CV GUI login
remains unchanged.
VDS disk array management not working
Use a process of elimination to determine whether the problem is with one of the following components:
Application m a naging the array
VDS
HP HWP
EVA disk array
Perform these tests:
1. Do the array volumes appear in the D isk M anagement tool? To check, in the Windows menu bar
select Star t > Control Panels > Administrative Tools > Computer Managem ent > Sto rage > Disk
Manag em ent. If array LUNs are not visible, click Action > Refresh and Action > Scan Disks.
2. Do the array volumes appear when you use the DiskPart utilit y ? At the Run command line,
type diskpart.exe.Typelist disk to see a list of disk devices present. (Type “help” to see a list
of commands.)
If you receive this error message: The disk manag em ent services could not complete the
operation, VDS is not enabled at startup. Click Start > Control Panels > Administrative Too ls >
Services >right-clickVirtual Disk Service > Properties >clickManual under Startup type and
click OK.
3. Check the Release Notes that came with your HP HWP installation les to verify you are using
compatible versions of software.
42
Troubleshooting