2. Set up and enable SNMP trap destination by running the command as following: set
snmp-parameters [enable crit|warn|info|none} [add-trap-hostaddress] [
del-trap-host adress][read-community string] [write-community string]
Table 3 SNMP parameters and its functions
DescriptionParameter
Optional. Sets the level of the trap notification:
crit: sends critical events only
warn : sends all critical events and warnings.
info: sends all events
none: All events are excluded from the trap notification and traps
are disabled.
enable
crit|warn|info|none
Specifies the IP address of the destination host to send traps to
add-trap-hostaddress
Deletes the specified host address
del-trap-host address
Sets an alpha numeric community string for Read-only access
read-community string
Sets an alpha numeric community string for writ-only access
Write-community string
Example 1.
set snmp-parameters enable crit add-trap-host 172.22.4.171
Success : SNMP parameters changed.
Getting SNMP traps from HP Storage P4000
SNMP Trap configuration is done using the HP LeftHand Centralized Management Console [CMS].
Configuring SNMP Traps involves the following activities:
Enabling an SNMP agent
Adding an SNMP client
Enabling SNMP traps
For more information on configuring SNMP traps, see the P4000 SAN User Manual.
Enabling an SNMP agent
To enable an SNMP agent, complete the following steps:
1. Log in to the storage node and expand the tree.
2. Select the SNMP category from the tree.
3. On the SNMP General tab window, click SNMP General Tasks and select Edit SNMP Settings.
4. Select the Enabled radio button to activate the SNMP Agent fields.
5. Enter the Community String.
6. [Optional] Enter System Location information for the storage node.
For example, this information may include the address, building name, room number, and so
on.